Small Molecule MicroED

Microcrystal electron diffraction (MicroED) is a structural technique that leverages the strong interactions of matter with electrons. MicroED services determine high-resolution structures from very thin micro- and nanocrystals. A transmission electron microscope is used to collect diffraction data, which is processed by standard crystallographic programs, allowing for rapid structure determination

Our MicroED workflow provides high resolution structures for challenging small molecule samples. It is particularly suited to studies when starting material is extremely limited or when growing large crystals for X-ray crystallography is challenging. With MicroED, crystals that are orders of magnitude smaller than those needed for X-ray crystallography can be used to yield high quality data. 

Small Molecule Studies From the Cryo-EM Experts

Small Molecule Studies From the Cryo-EM Experts

We have developed robust commercial MicroED services for small molecule studies to support a variety of industrial chemistry workflows. As one of the first providers of MicroED services, we have collected data from over 100 samples and solved more than 50 unique structures internally. Our structures have cleared up structure ambiguities, assigned absolute configuration, identified unwanted synthetic byproducts and guided polymorph selection for solid formulations. Solving a crystal structure early in the drug development process can expedite IND/NDA filing and ultimately strengthen your intellectual property.

Small Molecule Studies From the Cryo-EM Experts

We have developed robust commercial MicroED services for small molecule studies to support a variety of industrial chemistry workflows. As one of the first providers of MicroED services, we have collected data from over 100 samples and solved more than 50 unique structures internally. Our structures have cleared up structure ambiguities, assigned absolute configuration, identified unwanted synthetic byproducts and guided polymorph selection for solid formulations. Solving a crystal structure early in the drug development process can expedite IND/NDA filing and ultimately strengthen your intellectual property.

Leave it to us to go from sample to structure with a fast turnaround. Our experienced team can screen for diffracting crystals using X-ray powder diffraction (PXRD), collect MicroED data with our in-house developed automation software, process data on the fly and provide a fully refined structural model. Our team of expert crystallographers are able to tackle even the most challenging crystals and are staying abreast of this rapidly advancing field.

Small Molecule Studies From the Cryo-EM Experts

Small Molecule Studies From the Cryo-EM Experts

We have developed robust commercial MicroED services for small molecule studies to support a variety of industrial chemistry workflows. As one of the first providers of MicroED services, we have collected data from over 100 samples and solved more than 50 unique structures internally. Our structures have cleared up structure ambiguities, assigned absolute configuration, identified unwanted synthetic byproducts and guided polymorph selection for solid formulations. Solving a crystal structure early in the drug development process can expedite IND/NDA filing and ultimately strengthen your intellectual property.

Leave it to us to go from sample to structure with a fast turnaround. Our experienced team can screen for diffracting crystals using X-ray powder diffraction (PXRD), collect MicroED data with our in-house developed automation software, process data on the fly and provide a fully refined structural model. Our team of expert crystallographers are able to tackle even the most challenging crystals and are staying abreast of this rapidly advancing field.

No items found.

No items found.

Frequently Asked Questions

Explore how our experts can help you.

NIS Molecule

Why choose cryo-EM over other analytical methods?

Menu Hex
why-choose-cryo-em-over-other-analytical-methods

Cryo-EM allows for the direct visualization of biological molecules at moderate-to-high resolution without the need for crystallization, making it a powerful tool for structural biology. Additionally, cryo-EM can be used to study proteins in their native state, without the need for modification or crystallization, which can introduce artifacts or alter the structure of the protein.

Why should I use cryo-EM instead of X-ray Crystallography or Nuclear Magnetic Resonance (NMR) spectroscopy?

Menu Hex
why-should-i-use-cryo-em-instead-of-x-ray-crystallography-or-nuclear-magnetic-resonance-nmr-spectroscopy

Cryo-EM has several advantages over these techniques, including the ability to capture heterogeneous or dynamic molecular states in drug targets that are difficult or impossible to crystallize, including large (>300kDa) structures, protein:protein or protein:nucleic acid complexes, and membrane proteins. Additionally, cryo-EM requires smaller sample amounts than X-ray crystallography and NMR, using as little as 0.5-1 mg of protein at 1 mg/mL to obtain a structure. This can be particularly important for reagents generated from mammalian cells or are otherwise difficult to obtain. Overall, cryo-EM can address roadblocks with difficult samples such as preferred orientation, flexibility, aggregation, and more. Learn more about overcoming the challenges of preferred orientation in our blog post here.

Can we obtain additional/new information from cryo-EM after other methods failed?

Menu Hex
can-we-obtain-additional-new-information-from-cryo-em-after-other-methods-failed

Yes, cryo-EM can provide valuable information even after other methods have failed. Cryo-EM can visualize large and complex structures that are difficult to crystallize, and it can also capture dynamic states of proteins and macromolecular complexes that are not easily accessible through other methods. Additionally, cryo-EM can reveal conformational changes that occur in response to ligand binding or post-translational modifications, which may not be apparent from other techniques.

Is cryo-EM 3 Å resolution better than crystallography 3 Å?

Menu Hex
is-cryo-em-3-resolution-better-than-crystallography-3

It is difficult to compare the resolution of cryo-EM and crystallography maps solely based on a resolution limit since cryo-EM is a direct imaging method and the maps are not “phased” as in crystallography. As a direct method, the resulting maps from a cryo-EM data collection appear to be a “better” resolution than the refined nominal resolution may indicate. For instance, cryo-EM can provide structures with sidechains and small molecule ligand poses unambiguously defined at a nominal resolution of 3.5 Å, whereas density generated from a crystallographic experiment at that resolution cannot.

What is the likelihood of success for my sample?

Menu Hex
what-is-the-likelihood-of-success-for-my-sample

Each sample is different and we recommend an initial consultation with our team to provide an accurate estimation for success. NIS will always be fully transparent in regard to samples that might need more optimization or if a project might not be suitable for cryo-EM.

What kind of samples do you have experience with?

Menu Hex
what-kind-of-samples-do-you-have-experience-with

NIS has solved over 150 3D structures with cryo-EM, with 76% of protein structures solved at 3.5 Å or better resolution.

We have extensive experience with a wide range of samples for cryo-EM, including large (>300 kDa) and medium-sized (>100 kDa) proteins, with and without ligands of interest. We have also worked with proteins/nucleic acid complexes, multi-domain proteins, and multi-component complexes. We are experienced in handling challenging samples, including membrane proteins including  GPCRs and ion channels. Additionally, we have solved structures of complexes utilizing PROTACs and molecular glues, and have significant experience studying antibody:epitope interactions at moderate and high resolutions. Our team is dedicated to providing high-quality cryo-EM services to our clients and working with them to advance their research in diverse biological systems.

We are not sure if we can fully commit to a cryo-EM project. What are our options?

Menu Hex
we-are-not-sure-if-we-can-fully-commit-to-a-cryo-em-project-what-are-our-options

At NIS, we understand that committing to a cryo-EM project can be a big decision. That's why we offer a Starter Pack service, which includes a negative stain test and an initial feasibility assessment to help you evaluate the suitability of your sample for cryo-EM. The feasibility assessment can provide valuable information on sample quality and the potential for obtaining high-resolution structures. This service can help you make an informed decision about whether to proceed with a full cryo-EM project and can provide a cost-effective way to explore the capabilities of cryo-EM for your research. Read our blog about a proof of concept study here.

Are there size requirements?

Menu Hex
are-there-size-requirements

Ideally, your sample is at least 100 kDa of ordered mass. While less than 100 kDa is still feasible, the difficulty, timelines, and cost of the project will likely increase.

What quantity of my sample is required?

Menu Hex
what-quantity-of-my-sample-is-required

Cryo-EM has an advantage over other methods in that only a small quantity is required. 1 mg of your protein/complex at 1 - 5 mg/mL concentration is an appropriate starting target. Depending on your sample, we might ask for a higher concentration, however, this can be discussed with our technical team on a call.

Are all reagents and buffer conditions amenable to cryo-EM?

Menu Hex
are-all-reagents-and-buffer-conditions-amenable-to-cryo-em

Most reagents and buffer conditions are amenable to cryo-EM. Exceptions include DMSO >0.5% which may interfere with the vitrification process and cause crystal formation. Similarly, excessive glycerol or sucrose can increase sample viscosity and cause issues with particle alignment during data collection.

Do you do different concentration ranges, how does it work?

Menu Hex
do-you-do-different-concentration-ranges-how-does-it-work

If your project is feasible for cryo-EM, it may undergo several optimization steps where different concentrations/grid types will be tried. Protein concentration and buffer composition is a strong determinant of both ice thickness and particle distribution and is a primary variable tested during our feasibility assessment. Generally, soluble proteins are tested at 1-5 mg/mL concentration, while integral membrane proteins are better behaved at higher concentrations.

What is the wait time to start a project?

Menu Hex
what-is-the-wait-time-to-start-a-project

There is usually a 2-week lead time or less to initiate a project. It is best to ship your sample to us as soon as possible after your sample submission meeting, as there are frequent changes to schedules and microscope time can become unexpectedly available.

What are the turnaround times?

Menu Hex
what-are-the-turnaround-times

Turnaround times for structural biology projects are typically 4-8 weeks from sample to map, depending on the desired project goals. To obtain a more accurate timeline estimate, we recommend you set up an initial meeting with our team.

Do we prepare target proteins?

Menu Hex
do-we-prepare-target-proteins

At NIS, we specialize in providing high-quality cryo-EM services to our clients, and we do not offer protein preparation services. However, we recognize the importance of sample quality in obtaining high-resolution structures through cryo-EM, and we offer ‘gene-to-structure’ protein consultancy services to help our clients optimize their sample preparation and experimental design.

What is the timeline for protein production to structure?

Menu Hex
what-is-the-timeline-for-protein-production-to-structure

In our experience, protein production takes between 4-6 months at most structural biology CROs. From sample receipt to structure, the timeline is typically 4-8 weeks, depending on the difficulty of the project. To get a more accurate estimation of timelines, we recommend you set up a meeting with our experts.

What documentation does NIS handle?

Menu Hex
what-documentation-does-nis-handle

We support and value our clients IP confidentiality. Our in-house contracts team will work closely and efficiently with your legal team to execute all necessary contracts. A CDA/NDA usually takes about a week or less to complete, and an MSA usually takes about 2-3 weeks. We prefer to put a CDA/NDA in place before our introductory meeting so that the conversation we can discuss project specific details.

NIS Mountain Hero